This driver allows for communication with CIMON devices (PLCs, XPanels, IPCs) using a standard Serial connection. 

> Macro (toc)

# <span style="color: #0747a6">**Communication Settings: Canvas**</span>

|  |  |
| --- | --- |
| I/O Device Configuration | To create a new device, click **Tools **> **I/O Device Editor…** > click the **+ **icon > click **Serial **for Connection Type > select **CIMON CI-bus (CIMON-PLC) **for Device Type.<br>![image](media://e7730897-4146-4216-b81e-0d0eaba4e798) |
| I/O Device Settings | Once the connection type, device name, and device type have been assigned, the I/O Device Editor window populates with the default settings for the selected communication protocol.<br>![image](media://f5d41b86-91f4-4b86-86b4-272672a22e0c)<br>After selecting the correct Connection Type and Device Type, match the remaining settings to the target I/O device’s communication settings. |
| Station | In this window, users can assign a Station Name and ID for the target I/O Device.<br>![image](media://afd6c7eb-0a56-4bfd-8e65-2571088fd78d) |

 See the [Serial Communication Configuration](https://cimon.atlassian.net/wiki/spaces/CCANVAS/pages/4310827074) section for more information.

# <span style="color: #0747a6">**Communication Settings: PLC**</span>

|  |  |
| --- | --- |
| Communication Module | If using one of the following PLC modules to communicate with Xpanel, the card settings must be configured in CICON as shown below:<br>- CM1 - CN01M
- CM1 - CN01S
- CM3 - SP02ERS
- CM3 - SP02ERR
- CM3 - SP02ERC
- CM3-SP02ERSC
- BPnnMxxx - U<br>Note that the [CH 1] tab is for usage with RS232 connections, while the [CH 2] tab is for usage with RS485 connections. All communication parameters must match the settings chosen during the I/O device configuration in Canvas. Once the correct parameters have been entered, press the [Write] button while online with the PLC to update the communication parameters. |
| CPU Built-in Communication Port | If using a built-in CPU (PLC) serial port to communicate with Xpanel, the channel settings must be configured in CICON as shown below:<br>This connection option is available with the following models:<br>- CM1 - XP Series
- CM1 - CP Series
- BPnnMxxx - S
- PLC-S
  All communication parameters must match the settings chosen during the I/O device configuration in Canvas. |